==Description== |
==Description== |
||
− | + | Chinese handheld scopemeter, 2 inputs 60MHz & DMM 6000 pts |
|
Bought on [http://elec3i.com/oscilloscope-numerique/oscilloscope-portable-numerique-2x60mhz-dmm-6000pts-hantek-dso1060/product_info.php/cPath/23/products_id/32 this French e-shop] |
Bought on [http://elec3i.com/oscilloscope-numerique/oscilloscope-portable-numerique-2x60mhz-dmm-6000pts-hantek-dso1060/product_info.php/cPath/23/products_id/32 this French e-shop] |
Revision as of 11:07, 14 August 2010
Description
Chinese handheld scopemeter, 2 inputs 60MHz & DMM 6000 pts
Bought on this French e-shop
Internal data:
- Module DSO1060
- Serial No. DSO0000855
- Firmware Version: 1.68
- Hardware version: 5.2.34.0.0
USB memory stick
The device is USB-host capable but I had many troubles to get him accessing properly a memory stick.
On a 6Gb harddrive it hung when I tried to write a file, and on a 256Mb flash it was always claiming "Unknown Filesystem".
I finally managed to get it working by reformatting the 256Mb flash as FAT32 (FAT16 failed, or was it FAT12?)
Firmware upgrade
Once you have a working USB stick you can try upgrading the firmware.
I found the firmware version 1.70 here, follow simply the included pdf (the Chinese version is here).
If there is a newer version it should come via the same link I guess...
Issues
A known issue is in continuity test mode, it's rather slow to beep, which makes it much less usable than a cheap continuity tester...
Upgrade to v1.70 didn't improve the situation